| Fermilab Home | Beams Division | Fermilab at Work | NICADD Home | NIU Home |
Predicted performance of Injector II.
| Parameter | Predicted Value |
|---|---|
| Before Compression | |
| Bunch Charge | 8 nC = 5 · 1010e- |
| Laser pulse length FWHM | 28 ps |
| Launch Phase (w.r.t. Ez = 0) | 45° |
| Beam radius at cathode | 3.0 mm |
| Peak field on cathode | 35 MV/m |
| Post-Gun Gamma | 8.5 |
| Post-Linac Gamma | 35.7 |
| Transverse Emittance, normalized | 11 mm mrad |
| Longitudinal Emittance (100% RMS) | 820 deg keV |
| Momentum Spread | 4.2% |
| Bunch Length | 4.33 mm |
| Peak Current | 276 Amperes |
| After Compression, from theory | |
| Transverse Emittance, normalized | 15 mm mrad |
| Bunch Length | 1 mm |
| Peak Current | 958 Amperes |
| After compression, from PARMELA | |
| Transverse Emittance, normalized | 26 mm mrad |
| Bunch length RMS | 0.5 mm |
| Momentum spread RMS | 4.3% |
| Longitudinal Emittance | 760 deg keV |
D. A. Edwards, Editor, TeSLA Test Facility Linac--Design Report, Report TeSLA 95-01, DESY, Hamburg, Germany (March 1995), p. 97.
Updated 11 August 2001