Fermilab Home   Beams Division   Fermilab at Work   NICADD Home   NIU Home 

FNPL Parameters

Predicted performance of Injector II.

Parameter Predicted Value
Before Compression
Bunch Charge 8 nC = 5 · 1010e-
Laser pulse length FWHM 28 ps
Launch Phase (w.r.t. Ez = 0) 45°
Beam radius at cathode 3.0 mm
Peak field on cathode 35 MV/m
Post-Gun Gamma 8.5
Post-Linac Gamma 35.7
Transverse Emittance, normalized 11 mm mrad
Longitudinal Emittance (100% RMS) 820 deg keV
Momentum Spread 4.2%
Bunch Length 4.33 mm
Peak Current 276 Amperes
After Compression, from theory
Transverse Emittance, normalized 15 mm mrad
Bunch Length 1 mm
Peak Current 958 Amperes
After compression, from PARMELA
Transverse Emittance, normalized 26 mm mrad
Bunch length RMS 0.5 mm
Momentum spread RMS 4.3%
Longitudinal Emittance 760 deg keV

Source:

D. A. Edwards, Editor, “TeSLA Test Facility Linac--Design Report,” Report TeSLA 95-01, DESY, Hamburg, Germany (March 1995), p. 97.


Updated 11 August 2001